Skip to content

arch: attiny1634: Use built-in temperature calibration data - #76

Open
stcarlso wants to merge 1 commit into
ToyKeeper:trunkfrom
stcarlso:t1634-temp
Open

stcarlso wants to merge 1 commit into
ToyKeeper:trunkfrom
stcarlso:t1634-temp

Conversation

@stcarlso

Copy link
Copy Markdown

Improves the out of box thermal calibration of all attiny1634 lights by using the factory calibration data in the Device Signature register.

I do not have enough lights to do a large scale test of this one, but the temperature indicated after factory reset is much closer to the correct value on the two lights I tried (Emisar D1 v2 boost and Emisar D4K 2ch), within 2-3 degrees C.

@SiteRelEnby

Copy link
Copy Markdown
Contributor

Looks like it gives consistently reasonable results on a couple of my lights.

Improves the out of box thermal calibration of all attiny1634 lights by using
the factory calibration data in the Device Signature register.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment