Skip to content

hw: lumintop: fw3x-lume1: Fix voltage measurement - #181

Closed
stcarlso wants to merge 1 commit into
ToyKeeper:trunkfrom
stcarlso:fw3x-voltage
Closed

stcarlso wants to merge 1 commit into
ToyKeeper:trunkfrom
stcarlso:fw3x-voltage

Conversation

@stcarlso

Copy link
Copy Markdown

The 16-bit voltage measurement readout was truncated due to an incorrect cast to uint8_t. Avoid arithmetic overflow.

Tested on FW3X-lume1 hardware to correctly blink out the voltage; before, it would blink out nonsense numbers like 0.02 V.

The 16-bit voltage measurement readout was truncated due to an incorrect cast to uint8_t. Avoid arithmetic overflow.
@ToyKeeper

Copy link
Copy Markdown
Owner

Of course... the one I didn't test is broken. :D

Will have to see if I can find the adapter I used years ago to flash a fw3x. I didn't test because the flashing pins are swapped and I apparently misplaced the one adapter I had with remappable pins. But it's got to be around here somewhere...

@ToyKeeper

Copy link
Copy Markdown
Owner

Fixed in 026624c.

Thanks for finding this, testing it, and making a one-liner patch to fix it. I fixed it in a different way though, removing the broken code entirely so it can use the new voltage system.

I only have one FW3X to test it on, so I'm not sure how much hardware varies from one unit to another, but the calibration I used gives me results which are within 0.005V of the actual value. Hopefully others will be pretty close too.

@ToyKeeper ToyKeeper closed this Sep 20, 2026