Skip to content

Outputting of gravity wave diagnostics should be using pcols. #1603

Description

@nusbaume

What happened?

There are several gravity wave variables that are written to the history tapes with an ncol dimension, as can be seen here:

https://github.com/ESCOMP/CAM/blob/cam_development/src/physics/cam/gw_drag_cam.F90#L1568

However, these variables are actually dimensioned pcols, and thus using ncol results in non-physical grid imprinting on the values as they are written to the file.

What are the steps to reproduce the bug?

Do a run with the latest CAM development version with certain gravity wave variables, for example 'TAU_MOVMTN_A as reported by @JulioTBacmeister, and examine the values. You will likely see unphysical grid imprinting.

What CAM tag were you using?

cam6_4_184

What machine were you running CAM on?

CISL machine (e.g. derecho)

What compiler were you using?

Intel

Path to a case directory, if applicable

No response

Will you be addressing this bug yourself?

Any CAM SE can do this

Extra info

Credit should go to @JulioTBacmeister for both finding the bug and the method for fixing it.